SoliDrop
Welcome, Guest Sign InSign Up

25M/pc 25W 12Mm 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12Mm 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof
Price Tracker
Price Type
Price Desired
$
Your Email
Create aliexpress price watches
Product Details
  • Is_CustomizedYes
  • ApplicationHeating
  • Conductor MaterialCopper
  • Conductor TypeSolid
  • Insulation MaterialTeflon
  • TypeBare
  • Model NumberDxw-10J
  • Cable ColorBlack
  • Cable Length20 Meter
  • Cable Width10 Millimetre
  • Cable Safety Use LengthNot More Than 30 Meters
  • Cable TypeFlame Retardant
  • Cable Net Weight3.2 Kilogram
  • Cable Work Life4-7 Years
  • Cable Voltage220V/230V
  • Cable Temperature65 C
  • The Highest Temperatures105 C
Product Description
25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

Anti-freeze Frost Protection Heating Cable For Water Pipe/Roof 230V 12MM 30W/M 65Temp Self Regulating Electric Heater Copper Wire Description: Water lines and process pipe systems can become a real problem when temperatures drop below freezing. It\'s only when the thaw comes that you realize the damage a split or cracked water pipe can cause.Water Pipe Heating Cable provides a reliable heating solution to the problem of frozen pipe,it can prevent frost damages and keep liquids floating at all outside temperatures.
25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

Self-regulation - The self-regulating design of Raychem heating cables eliminates worry about overheating or burnouts from overlapping. The conductive polymer core automatically adjusts heat output at each point along the pipe, with no need for thermostats. Parallel circuitry - Unlike conventional heating cables, Raychem heating cables feature parallel circuitry. This means you can cut it at any point along its length without interrupti the heating-cable circuit. Fast, easy to install - Thanks to their self-regulating, parallel-circuit design, Raychem heating cables require no complex installation procedures. They can be straight-tracedspiraled, or overlapped. On the job, you can cut them to the exact length needed an splice or tee them, adapting each heating-cable circuit as the job requires. Reliable performance - Because they\'re self-regulating, Raychem heating cables require no thermostats, so you\'re not bothered by breakdowns or callbacks. They will protect against freezing this winter and for many winters to come. Designed flexibility - Hardwire them or plug them in. With two options of power connection kits, the choice is yours. There\'s even a preassembled heating cable available in convenient lengths to handle small jobs fast. Safe on plastic pipes - Raychem heating cables can be used on plastic as well as metal pipes. Their self-regulating heating core adjusts automatically, to protect against overheating or developing hot spots when overlapped or covered with insulation. Energy-efficient - Raychem heating cables\' self-regulating core generates heat when and where it\'s needed. The core continuously adjusts its heat output to the environment at every point along the heating cable, thus reducing the overall energy cost for the season. Features: The heating cable can prevent the freeze of the pipe and enable water to flow normally below 0°C Maintenance of the required temperature in pipes The heating cable uses thermostat to save energy. Thermostat -ON:6±3°C--OFF:13±3°C Easy installation Reliable operation Residential, Commercial or industrial applications Be suitable for use on plastic and metal water popes. This system can be installed with confidence and with the assurance that it will operate for years. Installation: first unwind the heating cable. The cable must never be connected to the power line when it is wound up. if the cable is too inflexible because of low temperatures, unwind it and put it for some minutes into the plug. afterwards you can pass the cable. the area around the pipe where you want to connect it with the cable must be accessibly and non-attached. the heating cable can not be passed behind walls put the thermostat with the round black contact area tightly on the coolest point of the pipe and fix it with insulating tape. finally put the whole cable on the pipe and fasten it every 30~60cm with insulating tape. attention: the cable must be fastening straight on the pipe now you can check if your cable works. afterwards insulate the water pipe and the heating cable with mineral rock wool or foam. Attention: never use more than 13mm of this material to insulate. in general the heating cable must be protected against mechanical damage or biting. the heating cable can not be put into liquids. finally plug the cable into a 230V main plug Characteristics(DHR series) Outerjacket standard color: black Max. working temperature: 65C Max. exposure temperature: 70C Max. working length: 100M Min. installation temperature: -40C Voltage: 220V/230V Power: 25w/m Min. bend radius: @20C:25.4mm @-30C:35.0mm Kindly remind: we are a manufacturer, we can do any size according to you demands. If you need other meter.please feel free to contact us. How to use it:
25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

25M/pc 25W 12MM 230V Commercial Snow Melting Heating Cable With Grounding Earth Screen Inside Water Pipe Water Proof

Self-regulation - The self-regulating design of Raychem heating cables eliminates worry about overheating or burnouts from overlapping. The conductive polymer core automatically adjusts heat output at each point along the pipe, with no need for thermostats. Parallel circuitry - Unlike conventional heating cables, Raychem heating cables feature parallel circuitry. This means you can cut it at any point along its length without interrupti the heating-cable circuit. Fast, easy to install - Thanks to their self-regulating, parallel-circuit design, Raychem heating cables require no complex installation procedures. They can be straight-tracedspiraled, or overlapped. On the job, you can cut them to the exact length needed an splice or tee them, adapting each heating-cable circuit as the job requires. Reliable performance - Because they\'re self-regulating, Raychem heating cables require no thermostats, so you\'re not bothered by breakdowns or callbacks. They will protect against freezing this winter and for many winters to come. Designed flexibility - Hardwire them or plug them in. With two options of power connection kits, the choice is yours. There\'s even a preassembled heating cable available in convenient lengths to handle small jobs fast. Safe on plastic pipes - Raychem heating cables can be used on plastic as well as metal pipes. Their self-regulating heating core adjusts automatically, to protect against overheating or developing hot spots when overlapped or covered with insulation. Energy-efficient - Raychem heating cables\' self-regulating core generates heat when and where it\'s needed. The core continuously adjusts its heat output to the environment at every point along the heating cable, thus reducing the overall energy cost for the season. Features:
Self-regulation - The self-regulating design of Raychem heating cables eliminates worry about overheating or burnouts from overlapping. The conductive polymer core automatically adjusts heat output at each point along the pipe, with no need for thermostats. Parallel circuitry - Unlike conventional heating cables, Raychem heating cables feature parallel circuitry. This means you can cut it at any point along its length without interrupti the heating-cable circuit. Fast, easy to install - Thanks to their self-regulating, parallel-circuit design, Raychem heating cables require no complex installation procedures. They can be straight-tracedspiraled, or overlapped. On the job, you can cut them to the exact length needed an splice or tee them, adapting each heating-cable circuit as the job requires. Reliable performance - Because they\'re self-regulating, Raychem heating cables require no thermostats, so you\'re not bothered by breakdowns or callbacks. They will protect against freezing this winter and for many winters to come. Designed flexibility - Hardwire them or plug them in. With two options of power connection kits, the choice is yours. There\'s even a preassembled heating cable available in convenient lengths to handle small jobs fast. Safe on plastic pipes - Raychem heating cables can be used on plastic as well as metal pipes. Their self-regulating heating core adjusts automatically, to protect against overheating or developing hot spots when overlapped or covered with insulation. Energy-efficient - Raychem heating cables\' self-regulating core generates heat when and where it\'s needed. The core continuously adjusts its heat output to the environment at every point along the heating cable, thus reducing the overall energy cost for the season. Features: Installation: first unwind the heating cable. The cable must never be connected to the power line when it is wound up. if the cable is too inflexible because of low temperatures, unwind it and put it for some minutes into the plug. afterwards you can pass the cable. the area around the pipe where you want to connect it with the cable must be accessibly and non-attached. the heating cable can not be passed behind walls put the thermostat with the round black contact area tightly on the coolest point of the pipe and fix it with insulating tape. finally put the whole cable on the pipe and fasten it every 30~60cm with insulating tape. attention: the cable must be fastening straight on the pipe now you can check if your cable works. afterwards insulate the water pipe and the heating cable with mineral rock wool or foam. Attention: never use more than 13mm of this material to insulate. in general the heating cable must be protected against mechanical damage or biting. the heating cable can not be put into liquids. finally plug the cable into a 230V main plug Characteristics(DHR series) Outerjacket standard color: black Max. working temperature: 65C Max. exposure temperature: 70C Max. working length: 100M Min. installation temperature: -40C Voltage: 220V/230V Power: 25w/m Min. bend radius: @20C:25.4mm @-30C:35.0mm Kindly remind: we are a manufacturer, we can do any size according to you demands. If you need other meter.please feel free to contact us. How to use it:
Installation: Characteristics(DHR series) Outerjacket standard color: black Max. working temperature: 65C Max. exposure temperature: 70C Max. working length: 100M Min. installation temperature: -40C Voltage: 220V/230V Power: 25w/m Min. bend radius: @20C:25.4mm @-30C:35.0mm Kindly remind: we are a manufacturer, we can do any size according to you demands. If you need other meter.please feel free to contact us. How to use it:
Kindly remind: we are a manufacturer, we can do any size according to you demands. If you need other meter.please feel free to contact us. How to use it:
Customer Reviews
Related Products