SoliDrop
Welcome, Guest Sign InSign Up

Heating Cable 230V 12Mm 25W/m 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Heating Cable 230V 12Mm 25W/m 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer
Price Tracker
Price Type
Price Desired
$
Your Email
Create aliexpress price watches
Product Details
  • Is_CustomizedYes
  • ApplicationHeating
  • Conductor MaterialCopper
  • Conductor TypeSolid
  • Insulation MaterialTeflon
  • TypeBare
  • Model NumberDxw-8J
Product Description
Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Self Regulating Heating Cable and Its Twine Installation Normal Standard+For Home Water Pipe With Earth Screen,Explosion-proof,Anticorrosive Can Use In The Inside Water Pipe/Sewer,Water-Proof 12MM Width Heating Cable Can Use In The -30 ~ -40 degree cslsius When the temperature rises, its resistance will also rise, reducing the heat generated .when the temperature rises to a certain value, within the current semi-conductive plastic down to the minimum, with heat generated close to 0. Outerjacket standard color: Black Width:12 MM Max. working temperature: 65C Max. exposure temperature: 70C Max. working length: 100M Min. installation temperature: -40C Voltage: 220V/230V Power: 25w/m Packing:5Meters
Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Features: 1.Energy efficient, self regulating heating cable uses less energy when less heat is required. 2.Easy to install, self regulating heating cable can be cut to any length (up to max. circuit length) in the field. 3.Field splices can be performed easily in minutes with no scrap or wasted cold sections. 4.lower installed cost than steam tracing, less maintenance expense and less downtime. 5.can be single overlapped without burnout, which simplifies heat tracing of in- line process equipment such as valves, elbows and pumps. 6.Because of self-regulating, over- temperature conditions are minimized. 7.termination, splice, tee and end seal kits reduce installation time
Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Key Specifications,Special Features:
1.Security , uniform temperature of heating cables pipeline 2.No overheat or burnout when overlapping 3.convenient for automation management 4.Energy saving,low installation and low operation cost,easy installation and maintenance 5.Heats up quick,rapid start when intermittent operation 6.Suitable for complex pipeline heat tracing 7.long-distance pipeline heat tracing 8.Suitable for instrument box antifreezing 9.Energy saving and long service 10.No pollution Applications: Self regulating heating cables have found worldwide applications in industry pipes and tanks heat tracing, indoor and outdoor heating systems, farming, control panel and electric systems, providing the best heating, warming, freeze prevention and snow melting solutions.
Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

We also supply all kinds of accessories.
Heating Cable 230V 12MM 25W/M 65 C With Screen Shield Screening And Can Use In The Inside Water Pipe And Sewer

Installation Notes: 1) Don\'t damage cable. The bend radius should be more than 6 times of thickness of cable. 2) Well installation can guarantee the efficiency. Use nylon cable ties to fix heat cables. 3) Add an aluminum tape between the pipe and the heat cables if the Pipe is non-metallic. 4) After the installation, take a full test and make sure the system works well. 5) Heat insulation materials should be dry and the joint of cable should be sealed. 6) Make a mark on the outer protective layer of the pipe. 7) The junction box should be sealed to prevent rainwater. 8) For explosion-proof products, the metal jacket should connected to the terminal. 9) Protective sleeve must not be damaged during installation, and the core wire can not bare. Features: Operate temperature Max. working temperature 65±5 Max. exposure temperature 85 Max. bearing temperature: modified polyolefin: 105; fire-retardant polyolefin: 105; fluorin-contained polyolefin: 180; fluorin material: 205 minimum installation temperature:-40 Application fields Pipe. tank freeze protection and process temperature maintenance ;Indoor and outdoor heating systems, freeze protection and snow melting. Service voltage 12v 24v 36v 110v 220v 380v Output power (at 10°C) 10w/m 15w/m 20w/m 25w/m 30w/m 35w/m 40w/m 45w/m 50w/m 55w/m 60w/m Thermostability After circulating for 300times from 10to 99, cable heat is maintained at 90% and above. Minimum bend radius At 20 :25.4mm; At -30 :35.0mm Insulation resistance if cable length is 100m and thermostatic water is 75 ,testing insulation resistance is 20MΩ at least. As for shielding or explosive-proof and protective type, test for 1 min between shielding layer and conductive wire core in 2,500VDC in 20, insulation resistance is 1200MΩ at least. Start-up crurrent ( 10 ) ≤0.7A/m Key Specifications,Special Features:
Applications: Self regulating heating cables have found worldwide applications in industry pipes and tanks heat tracing, indoor and outdoor heating systems, farming, control panel and electric systems, providing the best heating, warming, freeze prevention and snow melting solutions.
Installation Notes:
Customer Reviews
Related Products