  • Model NumberAp- C25 Ypv600
Product Description
TOWE AP - C25 YPV600 PV systems 600V DC System Power Class C protection, 3 modulus, Imax: 25KA, Up: 2.2V Thunder protector

Description
TPS series photovoltaic DC System Power Surge Protector

Application
LPZ 0-2 or higher interfacial area for lightning region, providing Class II and Class III protection coarse protection according to the size of PV systems through traffic. Suitable location to install surge protectors have a low-voltage AC power meter reverse side of the net and inverse DC input transformer, the AC output terminal, the inverter DC input side, install class II DC power surge protector, in the selection and use of PV combiner box is also reference to the above method to achieve the PV array surge protection.

Products Type
TPS-C25-YPV600 TPS-C25-YPV1000 TPS-C25-YPV1200 TPS-C40-PV600 TPS-C40-PV1000 TPS-C40-PV1200 TPS-B80-PV500 TPS-B80-PV700 TPS-B80-PV1200
Used in solar photovoltaic systems on buildings (Photovoltaic Power Generating System, referred to as PV systems), PV systems are usually installed in the open air, a large mounting area vulnerable to direct lightning and lightning electromagnetic pulse infringement; lightning surge on PV systems PV systems can damage the photovoltaic modules and inverters, TPS photovoltaic DC System Power Surge Protector Series is designed for surge protection PV system with a through flow 25ka, multi-40ka, 80ka three levels of extreme DC power surge protection module, there are built-in protection 6-way or 12-way lightning protection system of solar photovoltaic combiner box, can be applied to different voltages photovoltaic systems. TPS photovoltaic DC System Power surge protector products and other products with TOWE together, can constitute a comprehensive PV system, improve the lightning protection system.
Main features:
1 through flow, residual voltage, fast response, no freewheeling
2 Built-in thermal tripping device, so protection from overheating, breakdown failure can automatically disconnect
The modular design
3 Standard 35MM rail mounted, multi-pole module combination, very easy to install and maintain
4 window color display working status, normal green, red, indicating failure of the product
5 optional with remote communication terminals for remote alarm control

PV combiner box built-in lightning protection lightning protection modules have these characteristics, as well as the following key features:
1 can simultaneously access multiple solar photovoltaic arrays, each current up to 11A, to meet the different needs of users;
2 The Professional DC high voltage circuit breakers, DC voltage value is not less than DC1000V, safe and reliable;
3 lightning count function to facilitate the understanding of the situation and the frequency of lightning invasion of disasters;
4 with working status indicator, easy to observe working conditions;
5 equipped with a DC high voltage fuses and circuit breakers of two safety devices;
6 Protection rating of IP65, meet the requirements of outdoor installation, installation and maintenance simple and convenient.
Scope:
TPS photovoltaic DC System Power surge protector can be used LPZ 0-2 or higher interfacial area lightning region, providing protection class II and class III coarse fine protection for PV system according to the size of the flow through.
Suitable location to install surge protectors AC low pressure side and the reverse network meter inverter DC input, AC output. In the DC input side of the inverter, install Class II DC Power protection for photovoltaic combiner box is also reference to the selection and use of the above methods to achieve the PV array surge protection.

TPS-C40 2P

Usually installed at the output of the inverter, the wiring should be a ground wire, connect the negative cable, and finally connect the positive cable; positive and negative wire cable should be used more than 10mm2 multi-strand copper wire mine, ground should be used 16mm2 or more multi-strand copper wire connection. PV combiner box reference tank mine indicate connections and fixed. Surge protectors should regularly check the work, such as the protection window turns red indicating the deterioration of its front open space, when the fuse is tripped, timely maintenance or replacement module.

10~50 mm2

Usually installed at the output of the inverter, the wiring should be a ground wire, connect the negative cable, and finally connect the positive cable; positive and negative wire cable should be used more than 10mm2 multi-strand copper wire mine, ground should be used 16mm2 or more multi-strand copper wire connection. PV combiner box reference tank mine indicate connections and fixed. Surge protectors should regularly check the work, such as the protection window turns red indicating the deterioration of its front open space, when the fuse is tripped, timely maintenance or replacement module.